zodiac pool heater troubleshooting

Our pool is a little over a month old and we have not been able to use the heater yet. Neither fixed my problem. Zodiac Pool Heater Parts; Water Heater Replacement Parts. What is happening is we will use the heater to heat up the spa. This item: Zodiac R0457501 Hot Surface Ignitor Replacement for Zodiac Jandy Legacy LRZE Pool and Spa Heaters $216.46 Zodiac R0012200 Fusible Link Assembly Replacement Kit for Select Zodiac Jandy Pool and Spa Heaters $8.90 Wholesale Sensors Replacement for Jandy/Zodiac R0456500 Temp Sensor for Spa 12 Month Warranty $18.49 Compare with similar items Chemicals up to 38% OFF. Remove the basket and remove the debris with a hose. At seven-feet wide and under 3,500 lbs. The heater only comes on if its turned all the way up. I would presume the main PCB is dead. My name is Ron Walsh. Jandy lxi not heating, getting ignition fault, help, Jandy Lxi 400 - Fault - Check IGN Control - single flash light on FENWAL, Water flow issue with heater that throws a high limit switch (HLS) error code, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. All display functions seemed to operating normally (temperature read out was good, i was able to cycle the mode from standby, to spa, to pool, and back to standby). Whether through best-in-class products, or through industry-leading dealer loyalty program, Zodiac is the provider of choice for millions of people worldwide. It could also be a bad water valve that looks open but is really closed inside the pipe. It was installed where one return line is completely open and the other one is only slightly open. Per troubleshooting tips, it could be any of the following. For operation, heaters require a minimum GPM flow. Failure to follow warning notices and instructions may result in property damage. We offer great everyday prices, but If you see it for less, we will match that price! I replaced the temperature sensor and the circuit board. Only makes continuous clicking sound which I'm . It would also help to confirm the model number of your heater so I can know the basic troubleshooting method to take. Dont panic, instead, use our solutions to get out of this mess. ZODIAC is a registered trademark of Zodiac International, S.A.S.U., used under license. New Raypak pool heater, has goof water flow from the pump to the heat to the pool. This is something you should do around the house. Have you checked the circuit feeding the heater to make sure it is providing the proper voltage? Fill out a contact form to get a personalized response from our pool heating experts. The 2nd is after modified the 3-port valve to the return lines. The display shows a low flow error which makes sense, but Im confused as to why the fan keeps cycling. Water Is the heater flashing any error codes or making any off noises? No flame at burners. There is that possibility because of how it is made. Smith Water Heater Parts; Baxi Water Heater Parts; Bradford White Water Heater Parts; If the power at the valve, determine if gas is going into the pilot tube and pilot. If the supply valve is OFF, turn it ON. If the pool heater is running but not heating, ensure the heater thermostat is turned high enough. I read through the manual and found the whole ignition process (something like pre-blower, check air pressure sensor to let blower keep going, 15 second purge, then igniter gets warmed up, then gas, lastly flame sensor lets it stay on or kills the gas). 0000003209 00000 n Our volume discounts guarantee the absolute lowest prices on all of our products: swimming pool supplies, chemicals, equipment and more. Any other suggestions? Zodiac Australia provides swimming pool equipment, pool maintenance products, pool cleaners and pool care supplies including market leading brands such as Baracuda, Polaris, MagnaPool and iAquaLink. Dohenys is pleased to offer free next day delivery at no additional charge for orders over $100 to most of the US for all Doheny's brand chemicals and many of our most popular swimming pool supplies. This not only covers our brand name chemicals, but also our most popular swimming pool supplies. (Generates 173 code if Level II code 187 is present) Contact a pool professional. Pool Size: Average Overall Build Quality Value for Money Ease of Use Cleaning & Maintenance Noise Level Functionality I removed the front panel and I see the wiring and boards in there. Unfortunately, neither one of us have x-ray vision. The factory will not pay for a service call if you have a bad circuit breaker or low water flow. In order to take heat out of the air, the refrigerant inside the heat pump's evaporator tubes must be about 10 to 15F COLDER THAN THE AIR so at about 42 to almost 50F (5C) air temperature the heat pumps outside coil is approaching 32F (FREEZING-0C) and any moisture in the air will begin to FREEZE on the coil and ice it up.Icing clogs the small fins, insulates the tubes and stops air flow all of which severely reduce the efficiency. Is the pilot lighting? Heat pump will not run as LED panel says no water flow. 0000005942 00000 n Is the water to temp when the pump shuts off? CALL 800-536-1582. 0000001851 00000 n I have tried running it with the pump going full boogie to see if it is water flow problem and the service heater light still comes on. Your pool pump only moves a certain number of GPMs, therefore, too many water features can dramatically decrease your water flow. This is where my pool stops heating. I hope this helps. The igniter has a bit of carbon build up but came off with my finger. To avoid personal injury when working with pool chemicals, always wear rubber gloves and eye protection and work in a well-ventilated area. Use our interactive diagrams, accessories, and expert repair help to fix your Zodiac Heater . Zodiac is a leading global manufacturer of differentiated pool and spa products. So its been a month or more that it was running. SEARCH. https://amzn.to/3Bk70xWRaypak 406,000 pool heater stack adapter not included with heater and must have for indoor heater swaps. View and Download Zodiac Legacy LRZ installation and operation manual online. The EcoSmart Pool 27 is a tankless pool heater that saves space while raising pool temperatures by 1 to 1.5 degrees Fahrenheit every hour. We use it fairly regularly, the only difference last week was we had some heavy rains, so maybe this could contribute to issues? If it still is not working properly after you have done the above step, you should look for leaks in the hose. Apple is not a participant or sponsor of this promotion. However, the issue could also be caused by a lack of rotation of swivels on the top. Low ambient air temperature. The other 96.5% of the time, the heat exchanger can be bypassed so the pump works less saving electrical energy and up to $350 a year. For example, in some cases, you will see a Low Water Flow warning pop up on your heaters LCD screen. What happened to him?? We will even guarantee our Low Price for 30 days after your purchase. the heat pump must not be installed: -close to a heat source or to a source of inflammable gas, just happens when gets to correct temperature. Now this happens now and then since I bought the unit. I have a Raypak gas heater. 0000020514 00000 n First, determine the cleaners level of difficulty, and then choose from the list. Im sure the electrician did his best on the circuitry, but when dealing with a heater, you probably want to have an HVAC company take a look at the unit. IO Igniter open error If the control is not in lockout and senses that the igniter circuit is open when the blower is running the control will turn off the blower and go into lockout. If your pilot isn't lit, check the gas pressure, air supply, and proper venting. Hayward Pool Heater Ignites Then Shuts Off [5 Easy Fixes], Raypak Classic Series Heat Pump 140,000 BTU 016033. Zodiac LRZM LRZE Outdoor Vent Cap 400BTU | R0491605 Quantity: $196.10 36 Jandy Legacy Indoor Drafthood Kit LRZ Model Heaters 400K BTU | R0499605 Quantity: $225.79 37 Jandy LRZ Heater Adapter Plate 400K BTU LRZM LRZE | R0478305 Quantity: $23.30 38 R0500200 LRZM LRZE CLIP AllBTU Quantity: $19.88 39 All rights reserved. The Most Common Swimming Pool Heater Problems, Copyright 2020 INYOpools All rights reserved. Use an accurate pool thermometer. Fits Pentair EasyTouch pool and spa automatic control systems ; Measures 22-1/2-inch length by 5-3/4-inch height by 20-1/2-inch width ; Pentair Screenlogic App-Based Pool Controller. Confirm that all gas valve wiring is intact and connections are solid. Our customer service team is available Monday through Friday, 8am - 4pm EST. While doing so I disconnected the unit to make examining the heat exchange easier. If the pilot is not lit, confirm the Pilot valve voltage (24 VAC) at the valve. FAULTSHORTEDCOIL SENSOR-or-FAULTOPENCOIL SENSORIn the event that the coil temperature sensor malfunctions or is not connected the control will shut off the heat pump.FAULTSHORTEDWATER SENSOR-or-FAULT OPENWATER SENSORIn the event that the water temperature sensor malfunctions or is not connected the control will shut off the heat pump. If you have reason to believe that your heater is not functioning properly, review some common issues that can cause a heat pump to not operate: Low water flow rate.This is the number one issue for the heat pump not working. Close water features, or alternate them, until the pool heats to the desired temperature. Doheny's DIY Pool Care Help Center. However, the issue could also be caused by a lack of rotation of swivels on the top. If heat pump still does not heat, call for service.Heat pump does not run and control board displaysFAULTLOWWATER FLOWVerify circulating pump is on and all necessary valves are in the correct positions.Verify filter and skimmers are clean.Check water level in pool.Temporarily turn off all fountains and water falls that bypass the heat pump water inlet.If this does not correct the problem, call for service.Heat pump does not run and control board display showsFAULT HIGHREF PRESSUREVerify circulating pump is on and that there are no water flow restrictions to the heat pump.Make sure all necessary valves are open or in the proper positions to allow proper water flow to the heat pump.Verify filter and skimmers are clean. That would help go a long way in finding the solution. It clicks, but will not light. Important Safety Instructions, Page 7: Section 2. how can I tell if its bad ? If a lot of ice is allowed to build up it will take a long time to thaw out and melt.Heat Pumps are designed to shut off when the air can cause icing and automatically restart when it is safe again as the air temperature goes over 50F. The Pentair ScreenLogic2 . I only found 1 small stone stuck inside where the bypass is. No service system or service heater lights. If you are running your variable speed pump on the low setting, make sure you meet the minimum GPMs for your heater. Okay, Tony, I will ask the same question to you as well. Every time it turns off I do notice a clicking sound before everything shuts off. Parts4heating.com: Zodiac Pool Heater Troubleshooting Guides. You should also remove the cleaner from the pool, turn the wheels manually, and then disconnect the control box for 20 seconds. Wired setup is required for early generation iAquaLink systems. It doesnt sound like you have enough water flow. Monitor your PSI reading on your filters pressure gauge. So, whats the best way to fix it properly? When it comes to buying a Zodiac Pool Cleaner, your investment pays off. If no power, replace the board. Did you ever get this resolved? DIYin' it with Laughing Moms! Because next day delivery is not guaranteed for standard service and residential deliveries are made only Monday through Saturday though Saturday delivery is not guaranteed, there is a chance that our product will not arrive the next day. SYMPTOM CORRECTIVE ACTION Heat pump will not start, no control board display. Advice? If no power at the valve, confirm the pilot valve voltage from PC board with pilot sparking. It has been working fine all spring until now. Zodiac G2 troubleshooting, Changing the Diaphragm My Automatic Pool Cleaner is Not How to Change the Foot Pad for Zodiac G3 Pool Cleaner Without gas, the heater wont operate. Pentair Easytouch EasyTouch systems are available for a separate spa, a separate pool, or a pool/spa combination with shared equipment. Dohenys. West: 213-291-9276Southwest: 214-764-8551 Midwest: 312-229-0026 Northeast: 631-223-7175 Southeast: 239-247-5878. You have to open up the heater to find where the leak is coming from. After the heater fails to ignite, does the display stay on or go blank? Later located the water temperature sensor. 3-5 different H200 models have varying firing processes. 2012 - I suggest contacting the manufacturer to see if they will do a guided troubleshoot over the phone. Raypak Classic Series Heat Pump 140,000 BTU 016033. Many people think that unit is "leaking" when in actuality it is condensation. Has anyone ever had this code? Once done trying to turn on the heat threw FAULT-CHECK IGN CONTROL. Matthew hasnt been heard from since just after Tax Day. There are no diagnostics LEDs that flash. the instructions in this manual can be followed exactly. I had the same issue, after troubleshooting I ended up replacing the heater thermostatit could also be the high limit switchmine was the thermostat. If its of decent quality, youre most likely overlooking the proper length. Download. Pentair control system with smart phone app is very responsive and easy to adjust items such as temperatures, timers, etc. 877-346-4814. 26 Add To Cart Add to Compare Add to Wishlist Zodiac Valve Cap Z67395 11. Make sure the pilot tube is intact and not clogged. Zodiac Pool Systems, Inc., offers the following recommendations to help conserve fuel and minimize the cost of operating your pool heater without sacrificing comfort.

No Credit Check Farm Tractor Financing, Desocialization And Resocialization Examples, Articles Z

About the author

zodiac pool heater troubleshooting